Diskette Drive Checkout
Diskette Drive Checkout
Use the following procedure to isolate the diskette
problem to a controller, drive, or diskette.
For this test, you need
a scratch, write-enabled,
double-sided, high-density diskette
(2.0MB that formats to 1.44MB)
that is known to be good.
- Power-off the computer.
- Attach the external diskette drive
if it is not already attached.
- Power-on the computer.
Press the F1 key any time
while the POST memory count is proceeding.
When the memory test is completed, the Easy-Setup screen screen appears.
- Press the left or right arrow key to
select Test and press Enter
or position the pointer over the Test icon and
click the left click button once.
- Press Ctrl+A to enter the advanced diagnostics.
- Select the FDD-1 icon
and press Enter.
This runs the controller test and the drive
read/write test.
- If the controller test detects an error, FRU code 10 appears.
First, replace the diskette drive and cable and run the test again.
If FRU code 10 appears from this second test,
replace the top system board.
- If the controller test runs without errors,
select Tool
from the advanced diagnostics screen.
(See 'Running the Diagnostics' for instructions.)
Select the FDD-1 icon and
insert a scratch diskette
to continue with the drive test.
- Select the FDD-1 icon
from the advanced diagnostics screen
and press Enter.
- If the drive test detects an error, FRU code 50
appears.
Replace the drive or the drive cable.
- To exit from the test screen, press Esc.