Symptom/Error | FRU/Action |
---|---|
10X | 1. System Board |
110 | 1. Go to 'Memory Checkout' |
2. IC DRAM Card or DIMM Card | |
3. System Board | |
111 | 1. Go to 'Memory Checkout' |
2. Expansion Unit/Port Replicator | |
3. System Board | |
158 | 1. Set a HDP. |
(HDP was not set even | |
though the supervisor | |
password is set.) | |
159 | 1. Set a correct HDP. |
(HDP is not set the same | |
as the supervisor password.) | |
161 | 1. Go to 'Checking the Backup Battery' |
2. Backup Battery | |
3. System Board | |
163 | 1. Set Time and Date. |
(Time and Date was not set.) | 2. System Board |
173 | 1. Select OK in the error screen |
(Configuration data were lost.) | then set time and date |
2. Backup Battery | |
3. System Board | |
174 | 1. Check Device Configuration. |
(Perform | 2. System Board |
'Checking the Installed Devices List' | 3. Diskette Drive Assembly |
before changing any FRUs) | 4. Hard Disk Drive Assembly |
175, 177, 178 | 1. System Board |
183 | 1. Have the user examine the password. |
(Incorrect password entered | |
at the supervisor password | |
prompt.) | |
184 | 1. Reset the POP in Easy-Setup. |
(POP check sum error.) | |
185 | 1. Reset the startup sequence |
(The startup sequence is | in Easy-Setup. |
not valid. | |
Suspect that power was off | |
when the startup sequence | |
was being updated.) | |
186 | 1. System Board |
188 | 1. Set the system identification |
using the ThinkPad 750Ce | |
hardware maintenance diskette. | |
190 | 1. Go to 'Checking the Battery Pack' |
(Depleted battery pack was | |
installed when the power was on.) | |
191XX | 1. System Board |
2. Processor card | |
195 | 1. Check if the configuration was changed. |
(The configuration read | For example, check if the disk drive is |
from the hibernation area | from another computer |
does not match the actual | |
configuration.) | |
196 | 1. Run the hard disk drive test. |
(Read error occurred in the | 2. Hard Disk Drive |
hibernation area of the HDD.) | |
199XX | 1. System Board |
1XX | 1. System Board |
2XX | 1. Go to 'Memory Checkout' |
2. IC DRAM Card, DIMM, or DIMM Adapter | |
3. System Board | |
301, 303, 304, 305, 3XX | 1. Go to 'Keyboard / Auxiliary Input Device Checkout' |
2. Keyboard | |
3. Video Card | |
4. External Numeric Keypad | |
5. External Keyboard | |
6. Keyboard/Mouse Cable | |
7. System Board | |
601, 6XX | 1. Go to 'Diskette Drive Test' |
2. Diskette Drive Assembly | |
3. Diskette | |
4. System Board | |
602 | 1. Go to 'Diskette Drive Test' |
(Diskette read error.) | 2. Diskette |
3. Diskette Drive Assembly | |
604 | 1. Go to 'Diskette Drive Test' |
(Non-acceptable ID was read | 2. Diskette Drive Assembly |
from the diskette drive.) | 3. System Board |
11XX | 1. Serial Device (First) |
2. Communication Cable | |
3. System Board | |
12XX | 1. Serial Device (Second) |
2. Communication Cable | |
3. System Board | |
17XX | 1. Hard Disk Drive |
2. System Board | |
24XX | 1. System Board |
2. Video Card | |
808X | 1. PCMCIA Slot Assembly |
2. PCMCIA Device | |
3. System Board | |
860X | 1. External Mouse |
(Pointing device error when | 2. External Keyboard |
TrackPoint III is disabled.) | 3. System Board |
861X | 1. Reseat the keyboard Track Point III |
(Pointing device error when | cable at the interposer card |
TrackPoint III is enabled.) | See '2080 Keyboard Unit' |
2. Keyboard | |
3. External Mouse | |
4. Video Card | |
5. System Board | |
I9990301 | 1. Reseat the boot device. |
I9990302 | 2. Check the startup sequence for the correct |
I9990305 | boot device. |
3. Check that operating system has no failure | |
or is installed correctly. | |
I9990303 | 1. System Board |
Other codes not listed above | 1. Go to 'Undetermined Problems' |