Numeric Error Codes (TP 600/600E - 2645)


  Numeric Error Codes

Symptom / Error    FRU / Action in Sequence
10x 1. System Board
   101 Interrupt failure.  
   102 Timer failure.  
   103 Timer interrupt failure.  
   104 Protected mode failure.  
   105 Last 8042 command not accepted.  
   107 NMI test failure.  
   108 Timer bus test failure.  
   109 Low meg-chip select test.  
110 1. Go to 'Memory Checkout'
   (Planar parity.) 2. DIMM Card
  3. Detach the expansion unit if it is attached
      to the computer.
  4. System Board
111 1. Go to 'Memory Checkout'
   (I/O parity.) 2. Expansion Unit or Port Replicator
  3. System Board
158 1. Set an HDPs for the hard disk drive.
   (HDP was not set even though  
   the supervisor password is set.)  
159 1. Set the correct password for hard disk drive.
   (HDP is not set the same  
   as the supervisor password.)  
161 1. Go to 'Checking the Backup Battery'.
   (Dead battery.) 2. Backup Battery
  3. System Board
163 1. Set Time and Date
   (Time and Date were not set.) 2. System Board
173 1. Select OK in the error screen,
   (Configuration data was lost.)     then set the time and date
  2. Backup Battery
  3. System Board
174 1. Check Device Configuration.
   (Configuration error: Perform 2. Hard Disk Drive
   'Checking the Installed Devices List'. 3. System Board
   before changing any FRUs.)  
175, 177, 178 1. System Board
   175 EEPROM CRC #1 error.  
   177 Supervisor password check sum error.  
   178 EEPROM is not functional.  
17xx 1. Hard disk drive
   1701: HDD controller failure 2. System board
   1780, 1790 : HDD-0 error  
   1781, 1791 : HDD-1 error  
183 1. Have the user examine the password.
   (Incorrect password  
   entered at the supervisor  
   password prompt.)  
184 1. Reset the POP (power-on password) in Easy-Setup.
   (POP check sum error.)  
185 1. Reset the startup sequence
   (The startup sequence is not     in Easy-Setup.
   valid. Suspect that power was  
   off when the startup sequence  
   was being updated.)  
186 1. System Board
190 1. Go to 'Checking the Battery Pack'
   (A depleted battery pack was  
   installed when the power was on.)  
191xx 1. System Board
   (PM initialization error.)  
192 1. Fan
   (Fan error.) 2. System Board
195 1. Check if the configuration was changed.
   (The configuration read     For example, check if the DIMM is added
   from the hibernation area  
   does not match the actual  
   configuration.)  
196 1. Run the hard disk drive test.
   (A read error occurred in the 2. Hard Disk Drive
   hibernation area of the HDD.)  
199xx 1. System Board
   (Resume error.)  
1xx 1. System Board
2xx 1. Go to 'Memory Checkout'.
   201 Memory data error. 2. DIMM card
   202 Memory line error 00-15. 3. System Board
   203 Memory line error 16-23.  
   205 Memory test failure on on-board memory.  
   221 ROM to RAM remap error.  
225 1. Check if the supported DIMM is installed
   (Unsupported memory module) 2. DIMM card
   3. System board  
301, 303, 304, 305, 3xx 1. Go to 'Keyboard/Aux. Input Device Checkout'
   (301: Keyboard error.) 2. Keyboard
  3. External Numeric Keypad
  4. External Keyboard
  5. Keyboard/Mouse Cable
  6. System Board
601, 6xx 1. Go to 'Diskette Drive Checkout'.
   (601: Diskette drive 2. Diskette Drive assembly
   or controller error.) 3. Diskette
  4. System Board
602 1. Go to 'Diskette Drive Checkout'.
   (Diskette read error.) 2. Diskette
  3. Diskette Drive assembly
604 1. Go to 'Diskette Drive Checkout'.
   (Unacceptable ID was read 2. Diskette Drive assembly
   from the diskette drive.) 3. System Board
11xx 1. Serial Device
   1101: Serial_A test failure. 2. Communication Cable
  3. System Board
12xx 1. System board (Infrared)
   1101: Serial_B test failure.  
17xx 1. Hard Disk Drive
   1701 Hard disk controller failure. 2. System Board
   1780, 1790 Hard disk 0 error.  
   1781, 1791 Hard disk 1 error.  
24xx 1. System Board
   (2401: System board video error.)  
808x 1. PC Card slot assembly.
   8081 PCMCIA presence 2. PCMCIA device
   test failure. 3. System Board
   (PCMCIA revision number  
   also checked.)  
   8082 PCMCIA register  
   test failure.  
860x 1. External Mouse
   (Pointing device error 2. External Keyboard
   when TrackPoint is 3. System Board
   disabled.)  
   8601 System bus error-8042  
   mouse interface.  
   8602 External mouse error.  
   8603 System bus error or mouse error.  
861x 1. Reseat the keyboard cable.
   (Pointing device error     on the system board.
   when TrackPoint III is enabled.) 2. Keyboard.
   8611 System bus error-I/F     cable on the keyboard card.
   between 8042 and IPDC. 3. External mouse.
   8612 TrackPoint error. 4. System board.
   8613 System board or  
   TrackPoint error.  
I9990301 1. Check that the operating system is
   I9990302     installed in the HDD. If not, install
   I9990305     the operating system.
   I9990301 Hard disk error. 2. Reseat the boot device
   I9990302 Invalid hard disk 3. Check the startup sequence for
   boot record.     the correct boot device.
   I9990305 No bootable device. 4. Check that the operating system has
      no failure and is installed correctly.
I9990303 1. System Board
   (Bank 2 flash ROM check sum error.)  
Other codes not listed above 1. Go to 'Undetermined Problems'.