Running the PQA Diagnostics Program
- Attention - Before running the PQA Diagnostic Program,
make sure that the write enable tab of the Diagnostic Program Diskette is set to enable.
Boot from the Diagnostic Program Diskette and select "PQA System Diagnostics Program" from PC DOS 7.0
Startup Menu. The PQA main menu appears on the screen.
Please see the LEGAL - Trademark notice.
PQA Diagnostic Program Error Codes and Messages
Error Code/Message
FRU/Action in Sequence
16XX
Backup battery
RTC (backup battery) error
1XXX
° Reload BIOS default setting.
CPU or System board error
° CPU board
° System board
2XXX
° Reconnect CPU board.
Memory error
° DIMM
° System board
3XXX
° Reconnect keyboard.
Keyboard error
° Keyboard
° System board
4XXX
System board
Video error
5XXX
System board
Parallel port error
6XXX
System board
Serial port or
system board error
7XXX
° Diskette drive
Diskette drive error
° System board
8XXX
° Load BIOS default setting
Hard disk error
° Hard disk connection board
° Hard disk drive
9XXX
° Reconnect CD-ROM drive cable.
CD-ROM error
° CD-ROM drive
° System board
10XXX
° CPU board
CPU or System board error
° System board
11XXX
° TrackPoint board FPC cable
Pointing device error
° TrackPoint board
° Keyboard
° System board
Back to
Feel free - send a for any BUG on this page found - Thank you.