LCD ReIated Symptoms
Symptom/Error
FRU/Action in Sequence
LCD backlight not working.
1. Open the 'Display Properties' window in the Control Panel.
LCD too dark.
Check that the auto dim setting is not enabled under
LCD brightness cannot be
the 'Backlight' tab.
adjusted.
2. Reseat the LCD cable and connectors.
LCD contrast cannot be
3. LCD assembly
adjusted.
4. Inverter assembly
5. Mainboard
LCD screen unreadable.
1. Reseat the LCD cable and connectors.
Non-readable characters.
2. LCD assembly
Screen abnormal.
3. Inverter assembly
Wrong color displayed.
4. Mainboard
LCD has extra horizontal or
LCD assembly
vertical lines displayed.
LCD lid is loose.
1. Hinge Screws
2. Hinge group
Note: If you cannot find a symptom or an error in this list and the problem remains,
see 'Undetermined Problems'.
Please see the LEGAL - Trademark notice.