Power Supply Status Indicators (Netfinity 7000 - 8651)
Power Supply Status Indicators
To determine the status of a power supply, examine the following
indicators:
- Green Power-On light on the front of the server
- Amber Power-Failure light on the front of the server
- Green AC Power light on the back of the power supply
- Green DC Power light on the back of the power supply
If the green Power-On light on the front of the server is on,
and the amber Power-Failure light on the front of the
server is off, all power supplies are operational.
If the green Power-On light on the front of the server is on,
and the amber Power-Failure light on the front of the
server is on, a power supply has failed. Check the lights
on each of the power supplies.
NOTE: To ensure that the power supply is operational, both
lights must be on. Also check the power up
sequence, 'Power Up Sequence'.
The status conditions that the lights on the power supply indicate are:
AC Power Light |
DC Power Light |
Description |
On |
On |
The power supply is on and operating correctly. |
On |
Off |
Either the Power On/Off button is in the Off position (the Power-On light on the front of the server is off and the DC Power lights on all the power supplies are off) or this power supply has failed (the DC Power light on at least one of the power supplies is on). |
Off |
Off |
The server is not connected to an active wall outlet. |