RAID Diagnostic Error Codes




RAID Diagnostic Error Codes x270xxxx

The RAID controller error codes identify the type of adapter that failed and where the adapter is located within the system. All RAID controller diagnostic error codes adhere to the following template:

    0DDDPLST
     --+||||
       ||||+-------- Type of RAID controller
       ||||          0 = RAID Controller
       ||||          1 = IBM Fast/Wide Streaming RAID Adapter/A
       ||||
       |||+-------- System slot number for the controller
       |||
       ||+-------- Device LUN (value is always 0)
       ||
       |+-------- Device PUN (value is always 7)
       |
       +--------- 270 indentifies that the failure is in the
                      RAID controller.


Information relative to the failure mechanism experienced is encoded within the Failure ID that's included in the diagnostic's error message. The Failure Id is of the form:

    TTEE
    -+---+
     |   |
     |   +------- Identifies the error and is taken from E & F
     |            registers of the shared register set of the MIAMI
     |            chip.
     |
     +----------  Test number
     TT = 00  Memory Tests (DRAM)
          01  DRAM Test
          10  Transfer logic test
          11  MIAMI chip test
          14  Loopback test (through system memory)
          20  SCSI I/O processor test
          21  SIOP data test
          22  SIOP address test
          26  SIOP local loopback test
          30  SIOP/SCSI-Bus test
          31  SCSI Cable test
          32  SCSI Parity test
          40  MIAMI loopback test


RAID Logical Drive Errors x2710yyL

    02710RSL
         |||
         ||+---- RAID Logical Drive Return Code
         ||      0002 = One or more of the SCSI disks on which the
         ||             systemdrive is dependent does not respond.
         ||      0004 = Invalid systemdrive or attempt to check
         ||             non-redundant system drive (RAID 0).
         ||
         || All other = Logical drive test failed, resynchronization
         ||             required
         ||
         |+---- System slot number for the device
         |
         +---- Logical drive number


RAID Device Errors x271xxxx

    0271BCSP
        ||||
        |||+---- Device ID or PUN number of the device
        |||
        ||+---- System slot number for the device
        ||
        |+---- Channel number of the device
        |
        +---- Bay number of the device
   BCSP = 0002  Check condition, bad command
          0003  Request sense invalid status or bad command
          0005  Zero size, bad command
          0006  Bad block, read-verify test fail
          000A  Timeout, bad command
          000F  Unknown error, access problem, hard disk
                not responding.


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.