More Than Two DDD Drives, No RBL
More Than Two DDD Drives, No RBL
Note: The following procedure for multiple DDD drives assumes that the operating
system is installed on one of the DDD drives.
- View the ServeRAID log on another machine
and write down the order in which drives went defunct.
- Boot to the ServeRAID DOS Configuration
Diskette and choose View Configuration. Make sure that the
Channel Record Table
contains the correct information for the status of all drives, not just those
listed in the ServeRAID log.
- Using the ServeRAID Configuration Utility
program, choose Set Device State, then choose a DDD drive not listed in the
ServeRAID log to software-replace the drives. Change the state of this drive to ONL.
- Perform the previous step until only two DDD
drives are remaining. One or both of these drives should be listed as the first
drive(s) to go defunct as indicated in the ServeRAID log.
Note: If you choose the wrong order when you choose Set Device State to change
the drives' states to ONL, data corruption results.
Be sure that you only change device states to ONL for drives not listed as DDD in the ServeRAID log.
The first defunct drive requires rebuilding, so it must be replaced last.