Completing the installation
Completing the installation
Notes:
- Complete all the installation procedures for the
internal options that you have chosen to install.
- Read Safety Information.
- Ensure that all components have been reassembled
correctly and that no tools or loose screws are left
inside the server.
- Clear any cables that might impede the replacement
of the cover.
- Place the server in an upright position, and ensure
that the stabilizer feet are positioned correctly. For
more information, see
Stabilizing feet.
Note:
It is easier to install the cover if the server is
placed in an upright position.
- Install the side cover:
- Make sure that the cover lock (if present) is in
the unlocked position.
- Align the three bottom cover guides with the
corresponding notches on the frame of the server.
- Insert the bottom cover tab into the tab opening.
- With one hand, align the top so that the cover
rests against the server. With the other hand,
press the cover at the bottom left corner, above
the left rotated foot.
- Keep the hand at the top to hold the cover in
place. Use the thumb from the other hand to
slide the cover. Make sure that the cover is latched into position.
- If a cover lock is present, go to the back of the server
and lock the cover.
You can use the cover lock and keys to secure the
outside cover.
- Attention - In the
United Kingdom, by law, the telephone
cable must be connected after the power cord.
Caution: When the power-cord strain-relief bracket option
is installed on the power cord, the server must be plugged to a power source
that is easily accessible.
- Reconnect the cables to the back of the server, then,
plug the power cords into properly grounded electrical
outlets.
- If you have a modem or fax machine attached to the
server, and you are not in the United Kingdom,
reconnect the telephone line to the wall outlet and the
server, and plug the power cords into properly
grounded electrical outlets.
If you are in the United Kingdom, plug in the power
cords first, then, connect the telephone line to the wall
outlet and the server.
- Power-on the server and all attached devices.
- Attention - To allow
for air circulation, be sure to maintain the
following minimum clearances around the server:
- 102 mm (4 in.) in the front
- 127 mm (5 in.) in the rear
- 51 mm (2 in.) on the left and right sides
When you have completed installing the covers and
cables, go to
Updating the server configuration.