Quorum Modifications for the PC Server 325 Rack Cluster Example 1
Quorum Modifications for the PC Server 325 Rack Cluster Example 1
If you want to use the Microsoft Cluster Server program, you can modify this example configuration as
follows:
- Install two additional drives in the enclosure.
- Define the two drives as one RAID level-1 logical drive, then, use that logical drive as your quorum drive.
- In Server B, use the ServeRAID utility program to change the ServeRAID adapter Channel 3 SCSI ID from 7 to 6.
- Install a Third Channel Cable Option on the ServeRAID adapters in both servers.
Note: The part number for the ServeRAID II Third Channel Cable option is 76H5400. If you are
connecting ServeRAID-3H adapters to the Quorum drive, install the Third Channel Cable option provided with the ServeRAID-3H adapter.
- Attach an 8-mm to 68-pin converter, IBM Part Number 01K8017, to the external Channel 3 connector
on one of the ServeRAID adapters.
- Using a 4.3 meter cable, IBM Part Number 01K8029, connect Channel 3 of the ServeRAID adapter in
Server A to Channel 3 of the ServeRAID adapter in Server B.
Please see the LEGAL - Trademark notice.
Feel free - send a
for any BUG on this page found - Thank you.