Basic and Extended Configuration Status Codes
BCS
ECS
Explanation and Possible Recovery Action
Code
not
in
tableCode
not
in
tableExplanation: The ServeRAID adapter or controller is not
functioning properly.
Action: Have the system serviced.
00
01
Explanation: Invalid flash configuration.
Action: Start the IBM ServeRAID Configuration CD and
follow the instructions that appear on the screen.
If no instructions appear or if the problem persists, have
the system serviced.
00
02
Explanation: Invalid NVRAM configuration.
Action: Start the IBM ServeRAID Configuration CD and
follow the instructions that appear on the screen.
If no instructions appear or if the problem persists, have
the system serviced.
00
03
Explanation: Invalid flash and NVRAM configuration.
Action: Start the IBM ServeRAID Configuration CD and
follow the instructions that appear on the screen.
If no instructions appear or if the problem persists, have
the system serviced.
01
08
Explanation: No configuration was found in drives or
Online/Rebuild drives are not responding.
Action: Press F4, F5, F7, or F10.
01
18
Explanation: No configuration was found in drives; or,
Online/Rebuild and Hot-Spare/Standby Hot-Spare drives
are not responding.
Action: Press F4, F5, F7, or F10.
01
28
Explanation: No configuration was found in drives; or,
Online/Rebuild and Ready/Standby drives are not
responding.
Action: Press F4, F5, F7, or F10.
01
38
Explanation: No configuration was found in drives; or,
Online/Rebuild, Hot-Spare/Standby Hot-Spare, and
Ready/Standby drives are not responding.
Action: Press F4, F5, F7, or F10.
01
48
Explanation: No configuration was found in drives; or,
Online/Rebuild drives are not responding and unidentified
drives were found.
Action: Press F4, F5, F7, or F10.
01
58
Explanation: No configuration was found in drives; or,
Online/Rebuild and Hot-Spare/Standby Hot-Spare drives
are not responding and unidentified drives were found.
Action: Press F4, F5, F7, or F10.
01
68
Explanation: No configuration was found in drives; or,
Online/Rebuild and Ready/Standby drives are not
responding and unidentified drives were found.
Action: Press F4, F5, F7, or F10.
01
78
Explanation: No configuration was found in drives; or,
Online/Rebuild, Hot-Spare/Standby Hot-Spare, and
Ready/Standby drives are not responding and unidentified
drives were found.
Action: Press F4, F5, F7, or F10.
03
88
Explanation: A drive was imported from another system
and it has valid configuration; and, Online/Rebuild drives
are not responding.
Action: Press F4, F5, F7, or F10.
03
98
Explanation: A drive was imported from another system
and it has valid configuration; and, Online/Rebuild and Hot
Spare/Standby Hot-Spare drives are not responding.
Action: Press F4, F5, F7, or F10.
03
A8
Explanation: A drive was imported from another system
and it has valid configuration; and, Online/Rebuild and
Ready/Standby drives are not responding.
Action: Press F4, F5, F7, or F10.
03
B8
Explanation: A drive was imported from another system
and it has valid configuration; and, Online/Rebuild,
Hot-Spare/Standby Hot-Spare, and Ready/Standby drives
are not responding.
Action: Press F4, F5, F7, or F10.
03
C8
Explanation: A drive was imported from another system
and it has valid configuration; and, Online/Rebuild drives
are not responding and unidentified drives were found.
Action: Press F4, F5, F7, or F10.
03
D8
Explanation: A drive was imported from another system
and it has valid configuration; and, Online/Rebuild and
Hot-Spare/Standby Hot-Spare drives are not responding
and unidentified drives were found.
Action: Press F4, F5, F7, or F10.
03
E8
Explanation: A drive was imported from another system
and it has valid configuration; and, Online/Rebuild and
Ready/Standby drives are not responding and unidentified
drives were found.
Action: Press F4, F5, F7, or F10.
03
F8
Explanation: A drive was imported from another system
and it has valid configuration; and, Online/Rebuild,
Hot-Spare/Standby Hot-Spare, and Ready/Standby drives
are not responding and unidentified drives were found.
Action: Press F4, F5, F7, or F10.
07
08
Explanation: Online/Rebuild drives are not responding.
Action: Press F4, F5, or F10.
07
0C
Explanation: Online/Rebuild drives are not responding
and a drive was found at the incorrect SCSI ID.
Action: Press F4, F5, F6, or F10.
07
18
Explanation: Online/Rebuild and Hot-Spare/Standby
Hot-Spare drives are not responding.
Action: Press F4, F5, or F10.
07
1C
Explanation: Online/Rebuild and Hot Spare/Standby
Hot-Spare drives are not responding and a drive was found
at the incorrect SCSI ID.
Action: Press F4, F5, F6, or F10.
07
28
Explanation: Online/Rebuild and Ready/Standby drives
are not responding.
Action: Press F4, F5, or F10.
07
2C
Explanation: Online/Rebuild and Ready/Standby drives
are not responding; and, a drive was found at the incorrect
SCSI ID.
Action: Press F4, F5, F6, or F10.
07
38
Explanation: Online/Rebuild, Ready/Standby, and
Hot-Spare/Standby Hot-Spare drives are not responding.
Action: Press F4, F5, or F10.
07
3C
Explanation: Online/Rebuild, Ready/Standby, and
Hot-Spare/Standby Hot-Spare drives are not responding;
and, a drive was found at the incorrect SCSI ID.
Action: Press F4, F5, F6, or F10.
07
48
Explanation: Online/Rebuild drives are not responding
and unidentified drives were found.
Action: Press F4, F5, or F10.
07
4C
Explanation: Online/Rebuild drives are not responding, a
drive was found at the incorrect SCSI ID, and unidentified
drives were found.
Action: Press F4, F5, F6, or F10.
07
58
Explanation: Online/Rebuild and Hot Spare/Standby
Hot-Spare drives are not responding; and, unidentified
drives were found.
Action: Press F4, F5, or F10.
07
5C
Explanation: Online/Rebuild and Hot Spare/Standby
Hot-Spare drives are not responding, a drive was found at
the incorrect SCSI ID, and unidentified drives were found.
Action: Press F4, F5, F6, or F10.
07
68
Explanation: Online/Rebuild and Ready/Standby drives
are not responding; and, unidentified drives were found.
Action: Press F4, F5, or F10.
07
6C
Explanation: Online/Rebuild and Ready/Standby drives
are not responding, a drive was found at the incorrect
SCSI ID, and unidentified drives were found.
Action: Press F4, F5, F6, or F10.
07
78
Explanation: Online/Rebuild, Ready/Standby, and
Hot-Spare/Standby Hot-Spare drives are not responding;
and, unidentified drives were found.
Action: Press F4, F5, or F10.
07
7C
Explanation: Online/Rebuild, Ready/Standby, and
Hot-Spare/Standby Hot-Spare drives are not responding, a
drive was found at the incorrect SCSI ID, and unidentified
drives were found.
Action: Press F4, F5, F6, or F10.
09
00
Explanation: No error occurred.
Action: No action is required.
09
10
Explanation: Hot-Spare/Standby Hot-Spare drives are
not responding.
Action: Press F4, F5, or F10.
09
20
Explanation: Ready/Standby drives are not responding.
Action: Press F4, F5, or F10.
09
30
Explanation: Hot-Spare/Standby Hot-Spare and
Ready/Standby drives are not responding.
Action: Press F4, F5, or F10.
0F
00
Explanation: No error occurred.
Action: No action is required.
0F
10
Explanation: Hot-Spare/Standby Hot-Spare drives
are not responding.
Action: Press F4, F5, or F10.
0F
20
Explanation: Ready/Standby drives are not responding.
Action: Press F4, F5, or F10.
0F
30
Explanation: Hot-Spare/Standby Hot-Spare and
Ready/Standby drives are not responding.
Action: Press F4, F5, or F10.
Please see the LEGAL - Trademark notice.