Tape Drive Service Aids Menu
Tape Drive Service Aids Menu
The following steps download library firmware through the Service Aids menu.
- At the AIX command line, type tapeutil and press Enter. The tapeutil menu appears.
- Type 4 (Tape Drive Service Aids) and press Enter.
This selection also includes service aids for the tape library.
- Select Microcode Load from the Tape Drive Service Aids menu.
- Select the device from the Tape Drive Selection menu (for example, smc0).
- Enter the source file name or device on the Prompting for Source File menu.
The default source is the /dev/rfd0 diskette drive.
To load from a file, enter the path and filename (for example, /tmp/q2_150.bin)
The microcode load (or firmware) operation starts and a pop-up window is displayed after the operation is completed.
The media changer performs a power-on reset and reinitializes with the new firmware.
On the tape library operator panel, the display shows the new firmware level.