Hot-swap power supply installation
Hot-swap power supply installation
The server comes with one power supply. You can add a
second power supply to provide redundant power. After
you install a power supply, check the power supply status
indicators to verify that the power supply is operating
properly. See 'Power supplies' for details.
Never remove the cover on a power supply or any
part that has the following label attached.
Hazardous voltage, current, and energy levels are
present inside any component that has this label
attached. There are no serviceable parts inside these
components.
Refer to the following illustration while performing the steps
in this procedure.
Note:
You do not need to turn off the power to the server to
install hot-swap power supplies.
1 Screws
2 Filler panel
3 Power supply
4 Power-cord strain-relief bracket
5 Hole for shipping thumbscrew
6 Handle
7 AC Power light
8 Power cord connector for power supply 2
9 DC Power light
To add a power supply:
Never remove the cover on a power supply or any
part that has the following label attached.
Hazardous voltage, current, and energy levels are
present inside any component that has this label
attached. There are no serviceable parts inside these
components.
- Remove the filler panel 2:
- Remove the four screws 1 from the filler panel.
- Remove the filler panel 2 from the
power-supply bay and save it and the four screws you removed.
Note:
During normal operation, each power-supply
bay must have either a power supply or filler
panel installed for proper cooling.
- Place the handle 6 on the power supply in the open
position, and slide the power supply into the chassis.
- Gently close the handle 6 on the power supply to
seat the power supply in the bay.
- Plug the power cord for the added power supply into
power cord connector 8.
Caution:
If you install a strain-relief bracket option over the
end of the power cord that is connected to the
device, you must connect the other end of the
power cord to an easily accessible power source.
- Install a power-cord strain-relief bracket 4, if
desired.
- Plug the power cord into a properly grounded
electrical outlet.
- Verify that the dc Power light 9 and ac Power light
7 on the power supply are lit, indicating that the
power supply is operating correctly.