Installing a Non-hot-plug Adapter - Netfinity 5600 - Type 8664
Installing a Non-hot-plug Adapter
This section gives the procedure for installing a non-hot-plug adapter.
If you want to remove a non-hot-plug adapter, reverse the steps.
Before you begin:
Refer to the illustrations in 'Installing a hot-plug PCI adapter' while you perform the steps in this procedure.
To install a non-hot-plug adapter:
- Turn off the server and peripheral devices and disconnect all external cables and power cords
(see 'Preparing to install options'); then remove the cover.
See 'Removing the left-side cover (tower model)' or
'Removing the cover (rack model)'.
- Determine which PCI adapter expansion slot you will use for the adapter.
Note: Check the instructions that come with the adapter for any requirements or restrictions.
- Remove the expansion-slot cover -1-.
- Rotate the adapter retention latch -3- counterclockwise.
- Remove the expansion-slot cover from the server. Store it in a safe place for future use.
-Attention- Expansion-slot covers must be installed on all vacant slots.
This maintains the electromagnetic emissions characteristics of the system and ensures proper cooling of system components.
- Refer to the documentation that comes with the adapter for any cabling instructions.
It might be easier for you to route any cables before you install the adapter.
- Press on the touchpoint on the adapter retainer flap -4- at the end of the slot nearest the front of the
server and rotate the adapter retainer flap upward.
- Remove the adapter from the static-protective package.
-Attention- Avoid touching the components and gold-edge connectors on the adapter.
- Place the adapter, component-side up, on a flat, static-protective surface.
- Set any jumpers or switches as described by the adapter manufacturer.
- Install the adapter -8-.
- Carefully grasp the adapter -8- by its top edge or upper corners, and align it with the expansion slot on the system board.
- Press the adapter firmly into the expansion slot.
-Attention- When you install an adapter in the server,
be sure that it is completely and correctly seated in the system-board connector before you apply power.
Incomplete insertion might cause damage to the system board or the adapter.
- Lower the tab -2- on the adapter guide over the tab on the top corner of the adapter.
Rotate the adapter retention latch -3- clockwise until it snaps into place.
- Close the adapter retainer flap -4-.
- Connect any needed cables to the adapter.
-Attention- Route cables so that the flow of air from the fans is not blocked.
- If you have other options to install or remove, do so now; otherwise, go to 'Completing the installation'.