Error Symptoms
Error Symptom
FRU/Action
CD is not working properly.
1. Clean the CD
2. Try alternate CD
3. Clean the optical-head lens.
4. CD-ROM Drive
CD-ROM drive tray is not working.
1. Insert the end of a paper clip into the manual
(The server must be powered-on.)
tray-release opening.
If the server is on and the
2. CD-ROM Drive
tray does not eject,
CD-ROM drive is not recognized.
1. Run Configuration/Setup, enabled primary IDE channel.
2. Check cables and jumpers.
3. Check for correct device driver.
Diskette drive in-use light
If there is a diskette in the drive, verify that:
stays on, or the system
1. The diskette drive is enabled in the Configuration/Setup Utility.
bypasses the diskette drive.
2. The diskette is good and not damaged.
(Try another diskette if you have one.)
3. The diskette is inserted correctly in the drive.
4. The diskette contains the necessary files to start the server.
5. The software program is OK.
If the diskette drive in-use light stays on, or the system
continues to bypass the diskette drive, replace the diskette drive.
Monitor problems (general)
1. Monitor
Some IBM monitors have
2. Display Adapter/System Board
their own self-tests.
If you suspect a problem
with the monitor, refer to
the information that comes
with the monitor for
adjusting and testing instructions.