Undetermined Problems - Netfinity 5600 - Type 8664
Undetermined Problems
You are here because the diagnostic tests did not identify the failure,
the Devices List is incorrect, or the system is inoperative.
Notes:
- If you suspect a software mismatch is causing failures (solid or intermittent), be sure to see
'Resolving configuration conflicts'.
- A corrupt CMOS can cause undetermined problems.
Check the LEDs on all the power supplies.
If the LEDs indicate the power supplies are working correctly, return here and do the following:
- Power-off the computer.
- Be sure the system is cabled correctly.
- Remove or disconnect the following (one at a time) until you find the failure
(power-on the computer and reconfigure each time).
- Any external devices
- External surge suppressor/UPS devices
- Modem, printer, mouse, or non-IBM devices
- Each adapter
- Drives
- Memory-Module Kits (Minimum requirement = 1 bank of 128 MB DIMM
- Secondary microprocessor VRM, if installed
Note: Minimum operating requirements are:
Power supply
Processor board, use switch 3 on switch block 2 on the processor board to bypass the power switch button.
Verify that the power connectors J11 and J14 are installed correctly at both ends.
System Board
Memory Module kit Minimum requirement = 1 bank of 128 MB DIMM
- Power-on the computer. If the problem remains, suspect the following FRUs in the order listed:
- Power Supply
- Processor
- System Board
- Processor Board
Note: If the problem goes away when you remove an adapter from the system,
and replacing that adapter does not correct the problem, suspect the system board then the processor.