Termination (Internal SCSI Devices) (8650)
Termination (Internal SCSI Devices)
The devices at both ends of the SCSI bus must be terminated.
If you attach SCSI devices (internal or external), you must
terminate the last device in the chain.
NOTE:
All of the preinstalled hot-swap drives in the server have
automatic termination.
If you attach internal SCSI devices to one of the
SCSI-2 internal connectors in a non-disk-array model,
you must terminate the last internal device on the bus (cable) and
disable the termination on the other devices connected to the
internal SCSI controller. The SCSI-2 controller is already terminated.
Refer to the instructions that
came with the SCSI device for more information about termination.
Refer to the User's Reference for additional information about the
server's SCSI subsystem.
NOTE:
- A 16-bit cable connects the backplane to the SCSI-2 controller.
- A 16-bit to 8-bit SCSI Internal Converter is used to connect the
CD-ROM drive to the 16-bit cable.
- The external SCSI-2 connector requires
a 68-pin external cable connector.
- A CD-ROM drive is installed in bay A2.
In non-disk-array models the CD-ROM drive is terminated.