Modifying the UMA SETUP.ISS File Manually
The following provides a description of each acceptable value for the parameters that can be modified in
the SETUP.ISS file. Modify only the parameters that are listed in the following table. Do not modify any
other parameters. Use a text editor such as Notepad to modify the file. Save the file as SETUP.ISS.
Then, move the file to the same folder where the UMA installation files reside, and proceed with
'Performing a Silent Installation'.
Note: A sample SETUP.ISS file with the default settings can be found at 'Sample SETUP.ISS file'
Figure 2 UMA SETUP.ISS Values
Section Parameter Value
-------------------------------------------------------------------------------------------------------
[SdComponentDialogAdv2-0] | IBMDMICOMPONENTS-0=IBM | This entry installs the main components
| System Management Tools | of UMA, including the underlying
| | LANDesk Client Manager code . Do not
| | comment out this line unless you need to
| | reinstall one of the optional components.
|----------------------------------------------------------------------------
| IBMDMICOMPONENTS-1=IBM | This entry installs the LANDesk Client
| System Management Tools | Manager interface. Remove the
| | comment tag (;) if you want to include the
| | interface as part of the installation. This
| | entry has no affect on installing the
| | underlying LANDesk Client Manager code
| | as part of IBM System Management
| | Tools.
|----------------------------------------------------------------------------
| IBMDMICOMPONENTS-2=Enablement| This entry installs the IBM Netfinity
| for IBM Netfinity Manager | Services component. Remove the
| | comment tag (;) if you want to include
| | Netfinity Services as part of the
| | installation.
|----------------------------------------------------------------------------
| IBMDMICOMPONENTS-3=Enablement| This entry installs the client code required
| for Tivoli Framework | for UMA to integrate into the Tivoli
| | Framework product. Remove the
| | comment tag (;) if you want to include this
| | as part of the installation.
--------------------------|------------------------------|---------------------------------------------
[AskSecurInfo-0] | svUser= | This parameter defines the user ID that
| | will be used to log in to the UMA
| | program. The default value is Admin.
| | You can change this value to any value
| | up to 32 characters.
|----------------------------------------------------------------------------
| svPassword= | This parameter defines the user
| | password assigned to the user ID that will
| | be used to log in to the UMA program.
| | The default value is password. You can
| | change this value to any value up to 32
| | characters. Passwords are
| | case-sensitive.
|----------------------------------------------------------------------------
| svConfirm= | This parameter confirms the user
| | password. This value must match the
| | value in svPassword.
--------------------------|------------------------------|---------------------------------------------
[AskDestPath-0] | szPath= | This parameter defines the path to the
| | folder where the UMA program will be
| | installed.
--------------------------|------------------------------|---------------------------------------------
[AddAdminInfo-0] | szAlphanumericPager= | This parameter defines the telephone
| | number to be used by the Events,
| | Alarms, and Responses program to
| | access the primary pager. Include any
| | numbers required for an outside line. If
| | the number is outside of your local calling
| | area, you must also include the area
| | code and country code, if required. Only
| | numeric characters, commas, dashes, the
| | star symbol(*), and the pound symbol (œ)
| | are valid. Spaces and other characters
| | are not allowed.
|----------------------------------------------------------------------------
| szPINAlphanumericPager= | This parameter defines the PIN number
| | to be used by the Events, Alarms, and
| | Responses program to access the
| | primary pager. Only numeric characters,
| | commas, dashes, the star symbol(*), and
| | the pound symbol (œ) are valid. Spaces
| | and other characters are not allowed.
|----------------------------------------------------------------------------
| szAlternateAlphanumericPager=| This parameter defines the telephone
| | number to be used by the Events,
| | Alarms, and Responses program to
| | access the alternate alphanumeric pager.
| | Include any numbers required for an
| | outside line. If the number is outside of
| | your local calling area, you must also
| | include the area code and country code,
| | if required. Only numeric characters,
| | commas, dashes, the star symbol(*), and
| | the pound symbol (œ) are valid. Spaces
| | and other characters are not allowed.
----------------------------------------------------------------------------
szPINAlternateAlphanumericPager=| This parameter defines the PIN number
| to be used by the Events, Alarms, and
| | Responses program to access the
| | alternate alphanumeric pager. Only
| | numeric characters, commas, dashes, the
| | star symbol(*), and the pound symbol (œ)
| | are valid. Spaces and other characters
| | are not allowed.
|----------------------------------------------------------------------------
| szNumericPager= | This parameter defines the telephone
| | number to be used by the Events,
| | Alarms, and Responses program to
| | access the primary numeric pager.
| | Include any numbers required for an
| | outside line. If the number is outside of
| | your local calling area, you must also
| | include the area code and country code,
| | if required. Only numeric characters,
| | commas, dashes, the star symbol(*), and
| | the pound symbol (œ) are valid. Spaces
| | and other characters are not allowed.
|----------------------------------------------------------------------------
| szPINNumericPager= | This parameter defines the PIN number
| | to be used by the Events, Alarms, and
| | Responses program to access the
| | primary numeric pager. Only numeric
| | characters, commas, dashes, the star
| | symbol(*), and the pound symbol (œ) are
| | valid. Spaces and other characters are
| | not allowed.
|----------------------------------------------------------------------------
| szAlternateNumericPager= | This parameter defines the telephone
| | number to be used by the Events,
| | Alarms, and Responses program to
| | access the alternate numeric pager.
| | Include any numbers required for an
| | outside line. If the number is outside of
| | your local calling area, you must also
| | include the area code and country code,
| | if required. Only numeric characters,
| | commas, dashes, the star symbol(*), and
| | the pound symbol (œ) are valid. Spaces
| | and other characters are not allowed.
|----------------------------------------------------------------------------
| szPINAlternateNumericPager= | This parameter defines the PIN number
| | to be used by the Events, Alarms, and
| | Responses program to access the
| | alternate numeric pager. Only numeric
| | characters, commas, dashes, the star
| | symbol(*), and the pound symbol (œ) are
| | valid. Spaces and other characters are
| | not allowed.
|----------------------------------------------------------------------------
| szEmail= | This parameter defines the E-mail
| | address to be used by the Events,
| | Alarms, and Responses program to send
| | messages. Separate multiple e-mail
| | addresses with commas, spaces, or
| | semicolons. You can use up to 128
| | characters.
|----------------------------------------------------------------------------
| szAlternateEmail= | This parameter defines the alternate
| | E-mail address to be used by the Events,
| | Alarms, and Responses program to send
| | messages. Separate multiple e-mail
| | addresses with commas, spaces, or
| | semicolons. You can use up to 128
| | characters.
--------------------------|------------------------------|---------------------------------------------
[SdShowUserAndPassword-0] | szUserID= | This parameter is used for Windows NT
| | only. Type in user ID used to log in to
| | Windows NT. This value must match an
| | user ID that is defined for that specific
| | computer or for the domain. The value
| | can be in the form DOMAIN\UserID, where
| | UserID is a user on DOMAIN. It can also be
| | in the form of .\UserID, where UserID is
| | a user on the local NT machine instead of
| | a domain. If you install UMA and you're
| | simply logged into the local machine, and
| | not to a domain, then you'll see
| | MACHINENAME\UserID. This is equivalent
| | to .\UserID. It is preferable to use either
| | .\UserID or DOMAIN\UserID in SETUP.ISS
| | so you can use one SETUP.ISS file for
| | multiple machine rather than a custom file
| | for each machine.
|----------------------------------------------------------------------------
| szPassword | This parameter is used for Windows NT
| | only. Type in password assigned to the
| | User ID used to log in to Windows NT.
| | This value must match a password for a
| | user ID that is defined for that specific
| | computer or for the domain.
|----------------------------------------------------------------------------
| szConfirmation | This parameter confirms the Windows NT
| | log in password. This value must match
| | the value in szPassword.
-------------------------------------------------------------------------------------------------------
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.