Start (Check Procedures - Aptiva 2165 - SL-A)


Start

This is the entry point for all check procedures.
The check procedures use failure symptoms, Power-On Self Test (POST) error codes, or beeps to help determine the defective field replaceable unit (FRU).
Follow the suggested check procedures or use the diagnostics diskette to determine the problem FRU.


  -IMPORTANT- Replace FRUs ONLY when it is determined that the error is not a result of software, loose contacts, or dirty component surfaces.
Any FRU change should be verified by running a complete test
(See 'Diagnostics - All Tests' in PC-Doctor diagnostics program).

This book comes with a diagnostic program diskette, this diskette should be used ONLY with Machine Type 2165 Computer.
Do not use this diskette on other models.

POST error codes and error messages are displayed on the screen after the IBM logo.
A beep will precede each error code or message. Please refer to 'Index of Symptoms, Messages, Error Codes, or Beeps' for additional help.

All voltages in the check procedures are positive unless otherwise indicated.
Use frame ground for all voltage checks unless otherwise specified.

  -IMPORTANT- There is a voltage selector on the rear panel of the machine.
Use a flat-head screwdriver to turn the voltage selector to the voltage setting for the area in which you will be using the system.

NOTE: If the check procedures instruct you to replace a FRU and the error message persists, an option adapter card might be causing the failure.
Remove all option adapter cards, one at a time, until the error changes or the problem is no longer apparent.
Replace the last option adapter card removed.

The Recovery CD contains pre-loaded software that may reinstall the original software and recover the system.
Ensure data and programs of the hard drive have a backup copy.

How to Diagnose Combined FRUs: If an adapter or device consists of more than one FRU, any of the FRUs might cause an error code.
Before replacing the device or adapter, remove the FRUs one by one to see if the symptoms change.

If a newly replaced FRU does not correct the problem: If you have reached this point of the check procedures and were instructed to replace a FRU but doing so did not correct the problem, reinstall the original FRU and go through 'Start' again.

If you want to print a copy of a BIOS Setup Utility screen to an attached printer, press Print Screen key, while the following screen is displayed.

          PLEASE READ THE FOLLOWING: 
      Human Error is a cause for concern when applied to
      check procedures. It exists in every first time set of
      analysis procedures. It is therefore essential for
      effective and time-efficient servicing that each stage of
      every procedure be verified. (For example: When a
      symptom is found, or when a symptom appears to have
      been cured; the preceding steps should be repeated for
      accuracy of analysis.)


001 - START

To begin, note the following: