Start (Aptiva 2170/71/72/74/87/90 - SL-A)
001 - START Aptiva 2170/71/72/74/87/90 - SL-A
To begin, note the following:
002 - DOES AN IBM LOGO SCREEN APPEAR?
(YES, READ AHEAD. NO, GO TO STEP 004.)
- Insert diagnostics diskette in the diskette drive.
003 - DOES SYSTEM LOAD THE DIAGNOSTICS PROGRAM FROM THE DISKETTE DRIVE?
(YES, READ AHEAD. NO, GO TO STEP 004.)
004 - DO ANY MESSAGES, ERROR CODES, OR SYMPTOMS APPEAR?
(YES, READ AHEAD. NO, GO TO STEP 005)
005 -
006 - DOES THE SYSTEM CONFIGURATION REPORT CORRECTLY IDENTIFY THE DEVICES
INSTALLED IN SYSTEM? (YES, READ AHEAD, NO, GO TO STEP 007.)
- Select Diagnostics from the diagnostics program menu.
- Select and execute All Tests.
- Go to step 008.
007 -
- The system configuration report shows only those devices supported by the diagnostics diskette.
- If a device is missing from the list and is not factory installed, refer to the
service manual provided for that device.
(Refer to the Appendix C, 'Model/Monitor Configurations and FRU Part Numbers' to determine the
factory-installed devices in the model you are servicing.)
008 - DO THE DIAGNOSTICS FINISH WITHOUT ANY ERRORS?
(YES, READ AHEAD. NO, GO TO STEP 009.)
- If the Diagnostics \ All Tests did not detect a failure but the system still indicates a failure:
- Check all adapter card jumper settings.
- Check all adapter card switch settings.
- Check all adapter card cables and connectors.
Make sure that all of the above are set correctly and show the correct voltages and continuity.
Replace any defective cables or adapter cards. See 'Parts/Test Point Locations'.
- Run the Diagnostics \ All Tests again.
- If an error or other symptom is displayed, go to 'Index of Symptoms, Messages, Error Codes, or Beeps'.
- If no error can be detected or the symptom is intermittent, go to 'Undetermined Problems'.
- End
009 -
- If the last test stops and you cannot continue, first make sure all switches, power
connectors, cables, and jumpers are set correctly and show the correct voltages and continuity.
- Take note of any messages, error codes, beeps, or new symptoms.
Go to 'Index of Symptoms, Messages, Error Codes, or Beeps'.
- If there is no error symptom or the error symptom is intermittent, go to
'Undetermined Problems'.
Back to
Please see the LEGAL - Trademark notice.
Feel free - send a
for any BUG on this page found - Thank you.