Specifications 6868/6878
15) Maximum configuration weight depends on options installed.
Figures above are a system fully populated with options.
Feature
Description
Size
Depth: 460 mm (18.1 inches)
Height: 492 mm (19.4 inches)
Width: 200 mm ( 7.9 inches)
Weight
20.5 kg (45 lb) 15)
Environment
Air temperature:
- System on: 10° to 35°C (50° to 95°F)
- System off: 10° to 50°C (50° to 122°F)
Humidity:
- System on: 8% to 80%
- System off: 8% to 80%
Maximum altitude: 3048 m (10,000 ft)
Heat Output
Approximate heat output in BTUs per hour:
- As shipped: 361 BTU (106 watts)
- Maximum: 1564 BTU (460 watts) 16)
Electrical Input
Sine-wave input (50 to 60 Hz) required.
Low range input voltage:
- Minimum: 100 V ac
- Maximum: 127 V ac
High range input voltage:
- Minimum: 200 V ac
- Maximum: 240 V ac
Input kVA (approximately):
- Maximum (as shipped): 0.75 kVA
Airflow
Approximately 0.56 cubic meters/minute (20 CFM)
Acoustical
Noise Emission
ValuesAverage sound pressure levels:
At operator position:
- 44 dB operating
- 40 dB idle
At bystander position (1 meter):
- 40 dB operating
- 37 dB idle
Declared (upper limit) sound power levels:
- 5.5 bels operating
- 5.2 bels idle
16) Maximum power and heat specifications are based
on the 145-watt maximum capacity of the system power supply.
For additional information, see the ISO Supplier's Declaration
available from IBM.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.