Specifications Server 325-8639



Specifications (PC Server 325 - Type 8639)

 Size
   ° With pedestal:
      - Depth:   473 mm (18.6 in.)
                 569 mm (22.6 in.) with cable cover
      - Height:  455 mm (17.9 in.)
      - Width:   315 mm (12.4 in.)
   ° Without pedestal:
      - Depth:   473 mm (18.6 in.)
                 569 mm (22.6 in.) with cable cover
      - Height:  425 mm (16.7 in.)
      - Width:   195 mm ( 7.7 in.)
   ° Drawer model:
      - Depth:   465 mm (18.3 in.)
      - Height:  216 mm ( 8.5 in.)
      - Width:   482 mm (19.0 in.)
 Weight
   ° Typical server as shipped:  17.0 kg (37.5 lb)
 Environment
   ° Air temperature:
      - Server on:  10° to 35° C  (50° to 95° F)
        Altitude:    0 to 914 m (3000 ft.)
      - Server on:  10° to 32° C  (50° to 90° F)
        Altitude:   914 m (3000 ft.) to 2133 m (7000 ft.)
      - Server off: 10° to 43° C  (50° to 110° F)
        Maximum Altitude:  2133 m (7000 ft.)
   ° Humidity:
      - Server on:   8% to 80%
      - Server off:  8% to 80%
   ° Maximum altitude:  2133 m (7000 ft)
 Electrical Input
   ° Sine-wave input (50 to 60 Hz) is required
   ° Input voltage:
      - Low range:
         - Minimum:   90 V ac
         - Maximum:  137 V ac
      - High range:
         - Minimum:  180 V ac
         - Maximum:  265 V ac
      - Input kilovolt-amperes (kVA) approximately:
         - Minimum configuration as shipped:  0.08 kVA
         - Maximum configuration:  0.52 kVA
 Total Power Available for Drives
   ° Nominal Operating Current allowed:
      -  +5 Vdc line:  5.3 A
      - +12 Vdc line:  5.0 A
 Heat Output
   ° Approximate heat output in British Thermal Units (BTU) per hour:
      - Minimum configuration:  350 BTU  (102 watts)
      - Maximum configuration:  860 BTU  (251 watts)