SERVER INSTABILITY, HANGS, UNABLE TO INSTALL NOS


Subject: SERVER INSTABILITY, HANGS, UNABLE TO INSTALL NOS
New Netfinity server RETAIN Tip: 

    Record number:       H167340
    Device:              D/T8680
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O99/05/14
    Date last altered:   A99/09/28
    Owning B.U.:         USA

Abstract: SERVER INSTABILITY, HANGS, UNABLE TO INSTALL NOS


SYMPTOM:

Symptoms include but not limited to the following:

  1.  Not being able to install NOS
  2.  Errors while installing NOS
  3.  Errors while doing heavy I/O
  4.  System hangs during heavy I/O


PROBLEM ISOLATION AIDS:



Note: The background Autosynch that is performed right after RAID-5 Logical Drive creation is running and has not yet completed.


FIX:

Apply the following updates:



The referenced files are available from the following URL:

http://www.pc.ibm.com/searchfiles.html
search on "ServeRAID"


WORKAROUND:

This problem is only seen when the Autosynch is running on a RAID-5 Logical Drive with 10 or more physical drives.
The workaround is to wait until the Autosynch is finished before proceeding.